Martindale BZ701 Audible Socket Tester with Mains Polarity Check

Martindale BZ701 Audible Socket Tester with Mains Polarity Check

GBP £ 48.00

Manufacturer: Martindale

Users can identify 28 distinct socket fault conditions and proper wiring indicators with the Martindale BZ701 Audible Socket Tester with Mains Polarity Check. With the Blue Polarity Touchpad on the front of the device, users of the BZ701 can verify the polarity of the incoming supply. When the supply polarity is proper, a continuous buzzer and flashing green LEDs notify the operator. The buzzer will pulse and the LEDs will flash red if the polarity is off. Even after removing the finger from the touchpad, the alerts would still appear, necessitating more research. The BZ701 has a standby mode should the unit be inactive for ten minutes. In stand by mode the lights will extinguish and the central LED will flash Amber and the tone will alert the user every 5 seconds. The BZ701 is Cat III 300V rated.

  • 230V AC rms is the nominal operating voltage. 50 Hz is the operating frequency. Power usage: less than 2.5W Power: From the primary test socket In standby mode, the voltage low signal is &lt
  • 195V ± 5% after approximately 10 minutes. Indicator of high voltage: &gt
  • 270V ± 5% High indicator of earth neutral voltage: &gt
  • 30V nominal Reversal test (L-NE swap at incoming supply) for supply polarity
  • Verify the polarity of the incoming mains supply. There are 28 distinct fault indicators. Examine the socket wiring. Simple and rapid main socket testing indicator of high and low voltage Buzzer indicator and red/green LEDs for 28 different failure conditions N E L labeled LEDs enable fast fault source identification. After 10 minutes of inactivity, switch to standby mode.