Chauvin Arnoux CA6030 RCD Tester

Chauvin Arnoux CA6030 RCD Tester

GBP £ 694.80

Manufacturer: Chauvin Arnoux

In addition to typical RCD testing operations, the Chauvin Arnoux CA6030 RCD Tester is an advanced RCD tester that provides a number of helpful features. Using one of five pre-set milliamp currents (10, 30, 100, 300, or 500 mA) or a user-adjustable test current between 6 and 650 mA, it can perform RCD tests on standard, selective, A, and AC RCDs. Switchable L and N inputs enable a safe, dependable connection, and automatic voltage and frequency testing of installations adds more depth to tests. Earth loop and 1P earth measurements are two further crucial features of the Chauvin Arnoux CA6030, which also allows for non-trip RCD checks and trip time tests. Additionally, two-wire and three-wire phase rotation indications can be shown on the screen, and current and leakage current can be measured using an optional current clamp. The Chauvin Arnoux CA6030 offers printouts of results that are time- and date-stamped in addition to useful warning alerts that the user can customize. PC data transfer program comes pre-installed. Results are displayed on the illuminated, crisp display, and a "hands-free" bag with a cozy neck strap and an easy-to-use dial interface help with practicality. With its IP54 dust-proof rating and Cat III 600V safety certification, the Chauvin Arnoux CA6030 is safe to use in a variety of settings. A mains lead, a three-wire lead, three test probes, three crocodile clips, and a data transfer cable are included with the tester.

  • easurement of voltage and frequency Automatically when the installation is connected: 2. to 550 V (DC or RMS) / 15.3 to 450 Hz Differential examination I∆n = 10–30–100–300–500 milliamperes - Variable: from 6 mA to 650 mA Test for non-tripping: At ½ I∆n Measuring the trip time: At i, i+1, i+5, 150 mA, and 250 mA Measuring tripping current and time: Gradient from 0.5‒1.06 I∆n, with 3% steps Fault voltage: computed as I x RE, between 5.0 and 50.0 V. Up to 40 kA of short-circuit current can be shown by calculating IK = UREF / ZL-PE. Earth&#039
  • s orbit or living earth Through RCD testing with one auxiliary rod and without tripping: between 0.1 and 4000 °C computation of short-circuit current and fault voltage memory. Present assessment Phase rotation order with clamp connections 20 A (MN20 &amp
  • C172) or 200 A (C174) On installation frequencies between 15.3 and 64 Hz and voltage between 90 to 550 V, either sequentially (2 wires) or conventionally (3 wires)
  • tests A, AC, standard, and selective RCDs Test currents that are pre-set at 10, 30, 100, 300, and 500 mA One test current that can be adjusted between 6 and 650 mA Automatic frequency (450Hz) and voltage (550V) measurement Mains lead and movable L and N inputs Trip time tests and non-trip RCD tests Ramp and pulse modes Current measurement with an optional clamp Measurement of power on earth indicator of phase rotation (2- or 3-wire) Results are printable with a time and date stamp. 600V Cat III IP54 rated