DC current ranges from 30mA to 30A, and AC current ranges from 30mA to 20A, according to the Fluke i30 AC/DC Current Clamp. It may be used with a variety of other instruments because it measures through a 19mm jaw clamp and connects to testers using a standard 4mm shrouded banana plug. With a resolution of 1mA, the clamp provides values with accuracy within ±1%. A straightforward dial allows the user to modify the zero function. The clamp runs on a 9V battery and comes with a 1.5m cable. The Fluke i30 is classified as a Cat III 300V safety device and has a 30-hour battery life.
- Range of DC current: 30 mA to 30 A DC
Range of AC current: 30 mA to 20 A AC
Crest factor: 1.4 inches
Sensitivity of output: 100 mV/A
Accuracy: ±2 mA or ±1% of the reading
1 mA is the resolution.
<
- 100pF and >
- 10 k Ohms for load impedance
Sensitivity of conductor position: ±1% with respect to the center reading
Range of frequencies: -0.5 dB to 20 kHz (DC).
Coefficient of temperature: ±0.01% of reading/°C
9 V Alkaline power supply (MN1604/PP3)
30-hour battery life
Operating voltage: DC or 300 V AC rms
19 mm is the maximum conductor diameter.
4 mm safety connector is the output connection.
Output zero: Thumbwheel adjustment by hand
1.5 meters is the length of the cable.
Temperature range for operation: 0°C to +50°C
Temperature range for storage (without battery): -20°C to +85°C
15% to 85% is the operating humidity (non-condensing).
250 grams in weight
BS EN 61010-1:2001, BS EN 61010-2-032:2002, and BS EN 61010-031:2002 are the safety standards. Category III, EMC Standards: EN 61326: 1998 +A1, A2, and A3
- 300 V rms
- Pollution Degree 2
- DC current range: 30mA to 30A
AC current range: 30mA to 20A
19mm jaw clamp
Zero function
4mm shrouded banana connection