A highly advanced installation tester that can be used on single-phase and three-phase electrical installations, mobile generators, high- and low-frequency installations, machinery & switchboards, medical installations, electric vehicle charging stations, and much more is the Metrel MI3155 Eurotest XD Multifunction Tester. The Metrel MI3155's test features include: Testing for continuity Testing for earth resistance using three wires and two clamps ISFL, or initial fault leakage currents Testing of insulation monitoring equipment measuring insulation resistance testing of loops and lines (16Hz to 400Hz range) support for machine mode with time discharge test loop impedance evaluation of the short circuit current the three-wire PE test Phase sequence signal Evaluation of power and distortion (up to the 12th harmonic) Varistor testing RCD testing (general & selective, AC, A, F, B, B+, MI RCD, EV RCD, PRCD, PRCD-K, PRCD-S) Measurement of voltage (touch or contact with an external P/S probe) Advanced choices are available for the measuring functions of the Metrel MI3155. The loop impedance test feature includes two- and three-wire tests with a Trip Lock RCD feature, as well as four-wire testing on active transformers. RCD and impedance testing can also be conducted automatically. Meanwhile, continuity testing offers a 200mA test, a four-wire test, a 7mA test for PE conductors that does not trip RCDs, and more. Insulation resistance benefits from test voltages between 50V and 2500V with PI and DAR values, and insulation testing is automatically tested between L-N, N-PE, and L-PE. Industrial electricians will benefit greatly from the Metrel MI3155's advanced operating system. The user can programme sequences themselves or select from a variety of pre-set sequences for TT, TN/RCD, TN, and IT systems thanks to the device's AUTO SEQUENCE testing. When combined with an A1532 Electric Vehicle Charging Station Adaptor, the MFT is even suitable for EVSE testing. An easy-to-use interface and a colour touchscreen are used for operation. The Metrel MI3155 has clear push buttons that can also be used to navigate and start tests, in addition to fuse tables and helpful information displays. Results can be stored in a sizable onboard memory and transmitted via Bluetooth to a computer or smart device in a clear, logical database. The Metrel MI3155 has Metrel ES Manager software, which is great for report preparation, analysis, and data transfers, as well as rechargeable batteries as standard equipment. A 20m earth set, a plug commander, test leads, test probes, crocodile clips, a soft carry box, a USB cable, and a calibration certificate are additional accessories.
- Testing for Continuity:-
Test current 2-wire 7 mA
Ranges: from 0 to 19.99
- from 20 to 1999
Resolutions: 1 and 0.1
Accuracy (5% plus three digits)
200 mA for 2- and 4-wire tests
Ranges: 0 to 19, 20, and 200 to 1999.
Resolutions: 0, 1, and 0.01
Accuracy: (5% plus three digits), 10%, and 20%
Current:-
TRMS with AC and A1018, 20 MA range
Ranges include 0 to 99.9 mA, 100 to 999 mA, and 1 to 19.99 mA.
Resolutions: 0.1, 1 and 0.01 milliamperes
Accuracy: 5% of the reading plus five digits
- 3% of the reading plus three digits
- 3%
TRMS with AC and A1019, 20 MA range
Ranges include 0 to 99.9 mA, 100 to 999 mA, and 1 to 19.99 mA.
Resolutions: 0.1, 1 and 0.01 milliamperes
Accuracy: 5%
- 3%
- indicative
A1391, TRMS AC/DC, range = 40A
Ranges include 0A to 1.99A, 2A to 19.99A, and 20A to 39.9A.
Resolved: 0.01A, 0.01A, and 0.1A
Accuracy: (3% plus three digits), 3%, 3%
A1391, TRMS AC/DC, range = 300A
ranges from 0 to 19.99, 20 to 39, and 40 to 299,9 amps.
Resolutions: 0, 1, and 0.
Accuracy: (3% + 5 digits) indicative, indicative,
Ground Resistance:-
triple wire
Ranges include 0 to 19.99, 20 to 199.9, and 200 to 9999.
Resolutions: 0, 1, and 0.01
Precision: (5% plus five digits)
2 clamp
Ranges include 0 to 19.99, 20 to 30, and 30.1 to 39.9
Resolutions: 0, 1, and 0.
Accuracy: (10% plus 10 digits), 20%, and 30%
particular earth resistance
Ranges include 0 to 99.9, 100 to 999, 1 to 9.99, 10 to 99.9, and 100 to 9999 km.
Resolutions: 0.1 m, 1 m, 0.01 k, 0.1 k, and 1 k
Accuracy: 5% (up to 1999), 10% (2000–1999), and 20% (more than 20k)
Discharge Period:-
between 0 and 10
0.1% resolution
Precision: (5% plus two digits)
maximum voltage
From 0 to 550 volts
1V Resolution
Accuracy (5% plus three digits)
First Fault Leakage Current (IFSL):-
Isc 1, Isc 2
Range: 0mA to 19.9mA
Resolution: 0.1mA
Accuracy: ±(5% + 3 digits)
General:-
7.2V (4400 mAh Li-ion battery pack) power source
Category of overvoltage: 600V 300V Cat IV
- Cat III
Protective level: Added insulation
Bluetooth, USB, and RS-232 COM ports
lbs. 1.78 kg
Dimensions: 252 x 111 x 165 mm
Harmonics:-
Harmonics of voltage: 0.1V to 500V
THD of voltage: 0.1% to 99.9%
0A to 199.9A in terms of current harmonics and current THD
Electrical Resistance:-
50V, 100V, and 250V are the test voltages for R iso.
the following ranges: 0M to 19.99M, 20M to 99.9M, and 100M to 199.9M
Resolutions: 0, 1, and 0.
Accuracy: (5% plus three digits), 10%, and 20%
Test voltage: R iso, R iso all 500V/1000VTest voltage: R iso, R iso all 500V/1000V
the following ranges: 0 to 19.99M, 20M to 199.9M, and 200M to 999M
Resolutions: 0, 1, and 10 micrometres
Accuracy: 5%
- 10%
- (5% + 3 digits)
-
R-iso and R-iso all 2500 volts for testing
0 to 19.99M, 20 to 199.9M, 200 to 999M, and 1 to 19.99G are the available ranges.
Resolutions: 0.01MΩ
- 0.1MΩ
- 1MΩ
- 0.1GΩ
Accuracy: (5% plus three digits)
- 5%
- 10%
- 10%
DAR, PI
Ranging from 0.01 to 9.99 and 10 to 100
0.01 and 0.1 as resolutions
Precision: (5% plus two digits)
- 5%
AC and DC varistor tests
DC: 0V to 1000V
- AC: 0V to 625V
1V Resolution
Accuracy (3% plus three digits)
Impedance:-
Ipsc, Zline 4-wire, Zline (L-L, L-N)
Ranges include 0 to 9.99, 10 to 99.9, 100 to 999, and 1 to 9.99k.
Resolutions: 0, 1, 10, 1, and 0.01
Accuracy: 5% plus five digits
- 5% plus five digits
- 10%
- 10%
Ipfc, Zloop 4-wire, and Zloop (L-PE)
Ranges include 0 to 9.99, 10 to 99.9, 100 to 999, and 1 to 9.99k.
Resolutions: 0, 1, 10, 1, and 0.01
Accuracy: 5% plus five digits
- 5% plus five digits
- 10%
- 10%
RCD:-
RCD (t)
Ranges: 0 to 40 ms and 0 to the maximum time
0.10 milliseconds
Precision: 1 ms
- 3 ms
I-RCD Ramp
Ranges include 0.2 xl to 1.1 xl (AC, MI, EV a.c.), 0.2 xl to 1.5 xl (A, IN 30mA), 0.2 xl to 2.2 xl (B, MI, EV, d.c.), and 0.2 xl to 2.2 xl (N, IN 30mA).
Resolvency: 0.05xlN
Precision: 0.1xlN
RCD Uc
0 to 19.99 volts
- 20 volts to 99.9 volts
1V as the resolution
Accuracy: (-0% / + 15%) of reading fewer than 10 digits
-
Voltage:-
TRMS
From 0 to 550V
1V Resolution
Precision: (2% + 2 digts)
Frequency
ranges from 0 to 9.99 Hz and from 10 to 499.9 Hz
Resolutions of 0.01 and 0.1 hertz
Precision: (0.2% of the reading plus one digit)
Power:-
0W (VA, Var) to 99.9kW (kVA, kVar) of power (P, S, Q) Power element: Voltage THD: 0.1% to 99.9% from -1 to 1.
Illuminance:-
Type B
ranges from 0.01 to 19.99 Lux, 20 to 199.9 Lux, 200 to 1999 Lux, and 2000 to 19.99k Lux.Resolutions in Lux: 0.01, 0.1, 1, and 10
Accuracy: 5% (plus two digits), 5% (plus two digits), 5%, and 5%
Type C
range from 0.01 to 19.99 Lux, 20 to 199.9 Lux, 200 to 1999 Lux, and 2000 to 19.99k Lux.Resolutions in Lux: 0.01, 0.1, 1, and 10
Accuracy: 10% plus three digits, 10%, 10%, and 10%.
- Enhanced testing capabilities
Relevant to all industries
Customised and pre-set testing with AUTO SEQUENCE
Bluetooth wireless technology
Internal memory size
Suited to a variety of installations
Advanced touchscreen functionality
Several different test features