Chauvin Arnoux CA6472 Earth and Resistivity Tester

Chauvin Arnoux CA6472 Earth and Resistivity Tester

GBP £ 4,068.00

Manufacturer: Chauvin Arnoux

A very advanced device, the Chauvin Arnoux CA6472 Earth and Resistivity Tester can detect ground potential, earth coupling, soil resistivity (Wenner and Schlumberger models), continuity/resistance (two-wire or four-wire), and earth coupling. The tester is compatible with a variety of measuring methods, such as two clamp earth loop measurement, four pole, three pole, and four pole selected. Ground voltage can be measured between 0.01mV and 65V, while the tester's resistance range varies based on the measurement method employed. The maximum range is 0.01Ω to 99.9kΩ. The user can verify the effectiveness of the earthing structure in the event that lightning strikes the system over a very wide frequency range (41Hz to 5078Hz). The Chauvin Arnoux CA6472 is the perfect tool for both seasoned users and novices, thanks to its two working modes. Tests may be initiated automatically by pressing a single button once they have been chosen using a straightforward rotary switch. When interference voltages are present, the tester will select the most suitable frequency instead of doing the default test at 128 Hz. The tester can reject interference voltage up to 60 volts, which helps with accuracy. The user may obtain extra readings to aid in interpretation and analysis in Expert mode, as well as choose certain measurement parameters (frequency, voltage, frequency scan, etc.). Color-coded terminals, simple operation, and a helpful information sheet within the tester's lid make it easier to set up the Chauvin Arnoux CA6472 for testing. The tester also has automated input recognition, which helps with accuracy and safety by warning the user if any adjustments are missing or wrong. The device's internal memory can hold up to 512 test results, which may then be uploaded to a PC using the included USB connector and the Chauvin Arnoux DataView programme, which aids in the analysis and decoding of the statistics. With its IP53-rated housing, the Chauvin Arnoux CA6472 helps keep its user safe in hazardous or loud conditions while also keeping it dry and secure for field work. Together with two C182 clamps, data export software, a USB cable, a mains converter, and a cable for charging the battery, it also comes with a 12-month manufacturer's guarantee. Measurement Adaptor for Pylon Earth Chauvin Arnoux CA6474:- The Chauvin Arnoux CA6472's remarkable feature is its capacity to conduct testing on pylons that include earth cables when used in conjunction with the Chauvin Arnoux CA6474 Adaptor for Pylon Earth Measurements. Because it enables lightning to safely discharge to earth without harming the high-voltage cable, earthing is a crucial component of pylon structure. With the use of this test feature, it is safer and quicker to test earth resistance without having to disconnect the earth connection from a pylon.Because of the CA6472's wide frequency range, the tester and adapter can precisely and selectively detect the earth impedance of the structure by mounting four current sensors on the pylon's feet. When the two devices are used in tandem, measurements may be obtained for the following parameters: the total earth resistance of the line, the resistance of the pylon that is being tested, the resistance of each foot of the pylon, and the resistance of the earth cable that runs between the pylons.

  • DC Resistance Evaluation:- Correctness: ±(2% + 2 counts) Measurement range for auxiliary rods: 0.1Ω to 100kΩ Pair measurement: In agreement Indicator current: n/a Ranging from 0.001Ω to 99.9kΩ 41 Hz to 5078 Hz is the measurement frequency. Valence without load: ±16V DC Resolution: 0.011Ω to 100Ω for two wires / 0.001Ω to 10Ω for four wireszero Method of test: n/a Measuring method: three wires Maximum 60V peak interference for U Using Two Clamps for Earth Measurement:- ±(10% + 1 count) is the accuracy. Length of auxiliary rod: n/a Pair measurement: Not at all 1367 Hz for automatic measurement and 1611 Hz, 1758 Hz for manual measurement Evaluation current: n/a 16 or 32 Vrms is the no-load voltage. In between 0.01 and 500 Ω 0.01Ω to 1Ω is the resolution. How to test: n/a Measuring type: not specified Peak U interference: 60V at maximum Calculating Earth Potential:- ±(5% + 1 count) is the accuracy. Length of auxiliary rod: n/a Pair measurement: Not at all Frequency range of measurement: 41Hz to 128Hz Evaluation current: n/a 16 or 32 Vrms is the no-load voltage. 0 to 65 volts in range Resolution: 10 mV to 0.01 mV. How to test: n/a Three wires are the measuring kind. Peak U interference: 60V at maximum Selective Measurement of Four Poles/Four Poles:- The accuracy is ±(2% + 1 count). Measurement range for auxiliary rods: 0.01Ω to 100kΩ Measurement of the couple: None Frequency range for measurement: 41Hz to 5078Hz Current used for measurement: n/a Voltage at zero load: 16 or 32 Vrms Range: from 0.001Ω to 99.9kΩ Resolution: 10Ω to 0.001Ω Method of testing: n/a Four wires are used for the measuring type. U interference: Peak 60V at maximum In general,:- Weight and dimensions: 3.2 kg / 272 x 250 x 128 mm Electrical safety: CAT IV 50 V
  • meets IEC 61557-1-4-5, IEC 61010, and IEC 61326-1 standards. Memory/Communication: USB, optical link, 512 records IP53 protection rating Assessing Resistivity:- ±(2% + 1 count) is the accuracy. Length of auxiliary rod: n/a Pair measurement: Not at all Frequency range of measurement: 41Hz to 128Hz Evaluation current: n/a 16 or 32 Vrms is the no-load voltage. 0.01kΩ to 99.9kΩ is the range. 0.01 Ω to 100 Ω in resolution Wenner and Schlumberger test technique using automated computation Fourth wires as the measuring type Peak U interference: 60V at maximum Earth Pylon Measurement (using CA6474):- ±(5% + 1 count) is the accuracy. Measuring an auxiliary rod: 0.01Ω to 100kΒ Pair measurement: Not at all Frequency range for measurement: 41 Hz to 5078 Hz Evaluation current: n/a 16 or 32 Vrms is the no-load voltage. From 0.001Ω to 99.99kΩ in range 0.001Ω to 10Ω in resolution How to test: n/a Measuring type: not specified Peak U interference: 60V at maximum
  • Twelve-month guarantee Intelligent input identification possible to use the CA6474 Adapter to operate on pylon earths Two-wire or four-wire continuity/resistance The connection of Earth 41Hz to 5078Hz is the frequency range. measuring ground potential 0.01mV to 65V is the ground voltage range. 512 readings stored internally Rated IP53 for casing Range of maximum resistance: 0.01Ω to 99k.9Ω Interference voltage rejection (less than 60 volts) Soil resistivity (models of Wenner and Schlumberger) Four wire tests—two, three, or four Two C182 clamps that are provided are used for testing. Data transmission software and a USB cord