Chauvin Arnoux CA6417 Earth Clamp

Chauvin Arnoux CA6417 Earth Clamp

GBP £ 1,720.80

Manufacturer: Chauvin Arnoux

The Chauvin Arnoux CA6417 Earth Clamp metre is perfect for fast earth-loop resistance measurements in parallel earth networks because of its 35mm jaws, 600V CAT IV rating, and dangerous voltage alert. Perfect for applications where conductor access is restricted and for large conductors. The CA6417 Earth Clamp has a number of helpful features, such as automatic jaw calibration to assure precision, a HOLD button, and automatic PRE-HOLD when the clamp opened. It can concurrently display impedance and leakage current, earth voltage, and a breakdown of ground impedance. The CA6417 boasts an ergonomic design, a force compensation mechanism for effortless clamp opening, an OLED display that allows viewing across 180° in any lighting condition, and a rotary dial switch for selecting tests. It is extremely user-friendly. In addition to Bluetooth connectivity and the capacity to interface with GTC, DataView PC software, and/or the ANDROID app, the Chauvin Arnoux CA6417 Earth Clamp also comes with a carrying cover to keep the instrument safe. Applications for Specialists As ground stakes cannot be erected in urban settings, ground measurements are frequently challenging. Selective measurements on a parallel ground system can be made with the CA6417 ground clamp metre without ever disconnecting cables or putting up stakes. You can verify the continuity of the loop conductor tested in the case of regularly spaced ground connections or an underground ground loop by measuring low values using ground clamps.

  • Ammeter (Accuracy / Resolution / Measurement ranges (A) :- 1.000 to 2.990 mA - 3.00 to 9.99 mA / 10 µA / ±2 % ±50 μA 10.00 to 29.90 mA - 30.0 to 99.9 mA / 100 µA / ±2 % ±r 100.0 to 299.0 mA - 0.300 to 0.990 A / 1 mA / ±2 % ±r 1.000 to 2.990 A - 3.00 to 39.99 A / 10 mA / ±2 % ±r 4,000-count display 0.200 to 0.999 mA / 1 µA / ±2 % ±50 μA Frequencies :- 2,083 Hz is the measurement frequency. Frequency of transposition: 50, 60, 128 or 2,083 Hz General Parameters :- 1,440 measurements lasting 30 seconds each. Battery life Automatic calibration at startup Pairing: Bluetooth Class 2. 152-segment OLED display 48 by 39 mm Measurements: 262 x 95 x 55 mm Electrical safety: CAT IV, IEC 61010 600 V Clamping diameter maximum: Ø 35 mm Power supply: 4 NiMH or 4 LR6 (AA) alkaline batteries at 1.5 V IP40 protection 2000 time- and date-stamped measurements are stored. 935 g approximately, including batteries Ground voltage (V / V measuring ranges / V resolution) :- 0.1 / 0.1 up to 4.9 0.5 to 49.5 / 5.0 50.0-75.0% / 1 Loop inductance measurement (Accuracy / Resolution / Measurement ranges (µH)) :- 10 to 100 / 1 / ±5 % ±r 100 to 500 / 1 / ±3 % ±r Measurement ranges, resolution, and accuracy of a loop ohmmeter :- 0.010 to 0.099 / 0.001 / ±1.5 % ±0.01 0.10 to 0.99 / 0.01 / ±1.5 % ±2 r 1.0 to 49.9 / 0.1 / ±1.5 % ±r 50.0 to 99.5 / 0.5 / ±2 % ±r 100 to 199 / 1 / ±3 % ±r 200 to 395 / 5 / ±5 % ±r 400 to 590 / 10 / ±10 % ±r 600 to 1,150 / 50 / Approx. 20 % 1,200 to 1,500 / 50 / Approx. 25 % Measurement ranges, resolution, and accuracy of a loop ohmmeter :- 0.010 to 0.099 / 0.001 / ±1.5 % ±0.01 0.10 to 0.99 / 0.01 / ±1.5 % ±2 r 1.0 to 49.9 / 0.1 / ±1.5 % ±r 50.0 to 99.5 / 0.5 / ±2 % ±r 100 to 199 / 1 / ±3 % ±r 200 to 395 / 5 / ±5 % ±r 400 to 590 / 10 / ±10 % ±r 600 to 1,150 / 50 / Approx. 20 % 1,200 to 1,500 / 50 / Approx. 25 % Configure :- Z, V, and A configurations for alarms Active/Inactive automatic power-off Activated buzzer AUTOMATIC OR MANUAL HOLD Ahead of Hold Conventional or complex modes
  • Feature of automatic calibration LCD with backlighting Range of current: AC 20A to 0.5mA Present precision: +/- 2% 50µA to 100mA is the current resolution. 300 readings stored in internal memory. The loop impedance range is 0.01Ω to 1200Ω. Accurate loop impedance: ±1.5%–±20% Loop impedance resolution: 1 mΩ to 50 Ω Horizontal earth leakage clamp