Chauvin Arnoux CA6416 Earth Clamp

Chauvin Arnoux CA6416 Earth Clamp

GBP £ 1,360.80

Manufacturer: Chauvin Arnoux

A highly advanced earth tester, the Chauvin Arnoux CA6416 Earth Clamp can measure leakage current (0.2mA to 40A), loop resistance (0.01 to 1500Ω), and loop inductance (10 to 500µH). The metre gives extra ground voltage readings for a comprehensive view of circuit grounding, and the 35mm jaw clamp's shielded magnetic circuits make it immune to interference. With its remarkable measurement capabilities, the Chauvin Arnoux CA6416 is a suitable tool for a variety of tasks, including parallel ground testing on MV/LV installations, urban ground testing, working on telecommunication and railway cables, and subterranean or surface pipeline ground testing. The Chauvin Arnoux CA6416 is safe to use and has several useful functions. When ground voltage rises above a user-adjustable threshold, the clamp can sound an auditory and visual alert, and the assisted trigger makes it easier to use without tiring out. The Chauvin Arnoux CA6416 has an OLED display that can be seen from 180 degrees and is illuminated to accommodate various lighting scenarios. It has a hold function and may display the measurement result together with ground voltage, resistance, and loop inductance values all at once. Additionally, a pre-hold function that holds a reading on the screen when the clamp jaws are opened is a unique feature. The push buttons are quite easy to use with gloves on, and the clearly marked silicone dial makes it straightforward to use. The internal memory has the capacity to save and later retrieve up to 300 readings. The Chauvin Arnoux CA6416 comes with a convenient carry case and has a safety rating of Cat IV 600V. The 12-month manufacturer's guarantee and four AA batteries supply about 1440 measures of energy each.

  • Ammeter (Accuracy / Resolution / Measurement ranges (A) ):- 0.200 to 0.999 mA / 1 µA / ±2% ±50 μA per 4,000 counts 10 µA / ±2% ±50 μA / 1.000 to 2.990 mA - 3.00 to 9.99 mA 100 µA / ±2 % ±r - 30.0 - 99.9 mA - 10.00 to 29.90 mA - 0.300 to 0.990 A / 1 mA / ±2% ±r = 100.0 to 299.0 mA 1.000 to 2.990 A - 3.00 to 39.99 A / 10 mA / ±2 % ±r Frequencies:- 2,083 Hz is the measurement frequency. Frequency of transposition: 50, 60, 128 or 2,083 Hz Measurement ranges (V) / Resolution (V) for ground voltage:- 0.1 / 4.9 to 4.9 0.5 / 49.5 to 5.0 50.0 / 1 up to 75.0 General Specifications:- 1,440 30-second measurements during the battery&#039
  • s life Automatic calibration at startup Measurements: 262 x 95 x 55 mm 152-segment OLED display 48 by 39 mm Electrical safety: CAT IV, IEC 61010 600 V Clamping diameter maximum: Ø 35 mm IP40 protection Power supply: 4 x 1.5 V LR6 (AA) alkaline batteries or 4 x NiMH batteries 935 g approximately, including batteries Loop inductance measurement (Accuracy / Resolution / Measurement ranges (µH)):- 1 / ±5% ±r / 10 to 100 1 / ±3% ±r = 100 to 500 Loop ohmmeter (Accuracy / Resolution / Measurement ranges (Ω) :- 1.5% ±0.01 / 0.010 to 0.099 / 0.001 ±1.5% ±2 r = 0.10 to 0.99 / 0.01 1.5% ±r / 1.0 to 49.9 / 0.1 ± Between 50.0 and 99.5 / 0.5 / ±2% ±r 1/ 100 to 199 ±3% ±r Between 200 and 395 / 5 / ±5% ±r Between 400 and 590 / 10 / ±10% ±r 600–1,150 / 50 / About 20 percent Between 1,200 and 1,500 / 50 / About 25% Set up:- Z, V, and A configurations for alarms Active/Inactive automatic power-off Activated buzzer AUTOMATIC OR MANUAL HOLD Ahead of Hold Modes: Standard or advanced
  • Jaw clamp with ø35mm A 12-month guarantee Reading internal memory at 300 OLED backlighting 600V Cat IV Range of ground voltage: 0.1V to 75V Range of loop resistance: 0.01 to 1500Ω Range of loop inductance: 10 to 500µH Range of leakage current: 0.2 mA to 40 shows three readings simultaneously. Ground voltage alarms that are user-adjustable