Chauvin Arnoux CA6424 Earth Tester

Chauvin Arnoux CA6424 Earth Tester

GBP £ 612.00

Manufacturer: Chauvin Arnoux

For safe and simple 2P and 3P earth measurements, the Chauvin Arnoux CA6424 Earth Tester is the best tool. The users are assisted in avoiding connection issues by both text annotations and colour coding. With all measurements and functionality easily accessible on the front panel, which can be used even with gloves on, users are able to monitor voltage up to 600V. The CA6424 allows the user to immediately check the integrity of the H stake thanks to automatic start up in 2P earth measurement mode. The CA6424 calculates the differences in percentage proportion to the average while utilising the 3P earth mode and memorises the 52%, 62%, and 72% measurement values. If the difference is too great, a flashing display with the percentage value is shown on the screen. Thanks to the unique connection technology for the G72 clamp (optional), users can use the CA6424 to measure line (phase) current and leakage current from 0.5mA to 60A. The CA6424 contains a key specifically for cable compensation, and when a hazardous voltage is found, the LED screen flashes the NOISE sign to warn that there is noise voltage present. Measurement accuracy will be improved by the CA6424's automatic change from a frequency of 128Hz to 256Hz if a noisy environment is detected. With the CA6424's three displays and backlit screen, users may monitor useful measures, any errors in measurements or recorded values, as well as supplemental data like USE and HR, all on a single screen. The CA6424 is 600V CAT IV rated and complies with IEC 61557-1 and IEC 61557-4. The device has been drop tested to 1 metre as per IEC 61010-1 and is IP65 rated, providing protection from dust and low pressure water jets from any direction.The CA6424 is a 6 rechargeable battery-powered instrument with a battery life of up to 1500 measures at 3P earth measurements at 10 and a deactivatable automatic power-off feature.

  • Resistance 2P:- Accuracy: (2%R + 10 cts), (2%R + 2 cts), (2%R + 1 ct), etc. Compensation for cables: up to 5 Range: 0.05 to 99.99, 80 to 999.9, 0.800 to 9.999, and 8 to 50 thousand 0.01 / 1 / 10 / 100 as the resolution Resistance 3P:- Accuracy: (1%R+10 cts), (1%R+2 cts), or (1%R+1 ct) Average calculation: Calculating the average and the percentage of variation from the average Registers: RE @ 62%, RE @ 52%, RE @ 72% for data storage Frequency of measurement: 128 Hz or 256 Hz One-shot vs. ongoing measurement Voltage with no load: 10 V peak From 0.50 to 50,000. 0.01 / 0.1 / 1 / 10 resolution Measurement of current using an optional G72 clamp:- Accuracy: (1%R + 4 cts) / (1%R + 2 cts) Range: 8.00-60.00 A, 0.800-9.999 A, and 0.5-999.9 mA 0.1 / 1 / 10 mA resolution General Requirements:- Deactivatable automatic power-off feature Battery life: 1,500 times at 100 x 3P earth measurements IEC 61557 compliance: IEC 61557-1 and IEC 61557-5 Charger: Internal via included USB/mains adapter Display: Custom backlit 206 segment LCD Drop test: 1 m in accordance with IEC 61010-1 Environment: -10 to +50°C for operation and -40 to +70°C for storage (without batteries or accumulators) IK 04 according to IEC 50102 and IP 65 in accordance with IEC 60529 Measurement modes include V, I, R 2P and R 3P. Power source: six NiMH batteries that can be recharged
  • charging takes around six hours. Protection: Any input terminals up to 600 V Electrical safety standards include IEC 61326-1 for EMC and IEC 61010-2-030 for 600 V CAT IV. The Measuring of RH Stake Resistance:- Accuracy: (10%R + 1 ct). Range: 8 to 49.99 k/0.05 to 9.999 k 1/10th of a resolution USE a voltage metre:- Accuracy: (2 cts + 2%R) Range: 80.0 to 600 VAC / 0.10 to 99.99 VAC 0.01V/0.1V as the resolution Voltage:- Accuracy: (1%R + 1 ct) 0.1 to 600 volts 1V as the resolution
  • IEC 61010-1 1 metre drop test Resistance for 2P: 0.05 to 50 k 0.5 to 50 k for 3P Earth Rated at 600V CAT IV Automatically shutting down feature that is deactivable The G72 clamp measures current from 0.5 mA to 60 A. IEC 61557-1 and IEC 61557-4 compliance Rating: IP65 One-time or ongoing measurement modes Rechargeable NiMH batteries that can be used with a cigarette lighter, USB port, or power outlet RH stake resistance analysis USE voltage measurement Detection of voltages from 0 to 600V