Fluke 2052 Advanced Wire Tracer and Cable Locator Kit

Fluke 2052 Advanced Wire Tracer and Cable Locator Kit

GBP £ 1,464.00

Manufacturer: Fluke

Technical professionals can swiftly and precisely detect both energized and de-energized wires in walls, ceilings, and floors up to CAT IV 600V with the Fluke 2052 Advanced Wire Tracer and Cable Locator Kit. intended to shield users from potentially harmful transient overvoltages of up to 8000V that can arise in utility and industrial settings. All the necessary components for tracing wires and circuits are included in the kit. Test leads, test probes, round and blade outlet adaptors, and alligator clips are included in the accessory kit to connect the transmitter to electrical systems. The Fluke i400 current clamp, which can be used in loop mode to provide a boosted 6kHz signal through the insulation, is also included in the kit. Fluke 2052 The Fluke 2052 receiver has two modes of operation for signal detection in wires and cables: active tracing with the transmitter for all other modes and passive tracing without the transmitter for non-contact voltage detection. The receiver's tip makes it possible to trace junction boxes, orders, and confined spaces. The Fluke 2052 boasts a 2.5-inch color LCD screen and a backlight, making it usable in low light. The IP40-rated Fluke 2052 has undergone a 1-meter drop test. A sturdy transport case is also included with the Fluke 2052 Advanced Wire Tracer and Cable Locator Kit to protect it during storage and transit. Fluke 2000-T Transmitter The Fluke 2000-T Transmitter offers users three modes: high, low, and loop modes, and it can operate on both powered and unpowered circuits up to CAT IV 600V. Depending on the circuit being traced, the modes can be used to determine the induced signal's strength, which can yield more accurate findings. Both regular energized and de-energized circuits use the High Mode. When tracing precisely, low mode can be employed to minimize coupling to adjacent wires and metal objects by using a low signal. Circuits with closed loop de-energization operate in loop mode. When utilizing the 2000-T, the device will choose an output frequency of either 6 kHz or 33 kHz based on its ability to detect whether the system is powered on or off. Eight receiver sensitivity settings offer increased adaptability

  • 2052R Audio Device Quantification Kind: CAT IV 600V Working Voltage: AC/DC 600V Regularity of operation: 6.25kHz is the activated frequency. Deactivated: 32.768 kHz Signal indicators include an audio beep and a numerical bar graph display. Reaction time: Tip sensor: 500 ms (energized/deenergized)
  • 500 ms (NCV). Battery observation: 5 sec Range finding in the open: Pointer Sensor: Invigorated: Maximum flying distance: 6.1 m (20 ft)
  • approximate pinpointing distance: 5 cm (1.97 in). Pointer sensor: De-energized Maximum aerial distance: 4.5 meters (14.7 feet)Pinching: around 5 centimeters (1.97 inches) NCV: 40 Hz – 400 Hz Maximum sensitivity: 90V to 2 meters? Sensitivity minimum: 600V to 1 cm Display LCD display size 63 mm, or 2.5 in. The display&#039
  • s measurements are 37 x 49 mm, or 1.45 x 1.93 inches. Pixels in the display: 240 x 320 Display Color: 16-bit Display Type: TFT LCD Backlight: In agreement Environmental Operating temperature range: -4°F to 122°F (-20°C to 50°C) -20 °C to &lt
  • 10 °C or 40 °C to 50 °C (-4 °F to &lt
  • 50 °F or 104 °F to 122 °F) is the operating humidity of 45%. 10 °C to &lt
  • 30 °C (50 °F to 86 °F) is the 95% non-condensing range. 75%: 86 °F to 104 °F, or 30 °C to &lt
  • 40 °C Operating altitude: 6581 feet, or 2000 meters Degree of pollution: 2. IP40 classification 1.m (3.28ft) drop test Mechanical Battery power: four AA batteries Typical power usage is 110mA. Battery life: roughly sixteen hours Low battery warning: Indeed. Dimensions: 183 x 75 x 43 mm (7.2 x 2.95 x 1.69 in) (L x W x H) Weight: around 0.6 lbs (0.27 kg) 2000T Transmitter Quantification Kind: CAT IV 600V Working Voltage: AC/DC 600V Regularity of operation: 6.25kHz is the activated frequency. Deactivated: 32.768 kHz Signal indicators include an audible beep and LEDs. Time of response: Line One-second voltage NCV: 500 ms Battery observation: 5 sec Signal current output (typical): Circuit that is energized: 60 mA rms in high mode and 30 mA rms in low mode Disconnected circuit: 110 mA rms in high mode, 40 mA rms in low mode, 160 mA rms in loop mode with test leads, and i400 AC current in loop mode 385mA rms for the clamp Nominal signal voltage output: Circuit that is energized: In the high mode, the power output is 14W at 230V ac/50 Hz while the low mode is 4.6 W at 230V ac/50 Hz and 11.5 kΩ at 230V ac. Disconnected circuit: High mode: 0.86 W @ 1 kΩ load, 31 V RMS, 140 Vp-p Low mode: 120 Vp-p, 0.1 W @ 1 kΩ, 27.5 V RMS Display Display size: LEDs Display Type: LEDs Display Colour: Operating Mode LEDs: red Battery Status LEDs: green, yellow, red surroundings Operating temperature range: -4°F to 122°F (-20°C to 50°C) -20 °C to &lt
  • 10 °C or 40 °C to 50 °C (-4 °F to &lt
  • 50 °F or 104 °F to 122 °F) is the operating humidity of 45%. 10 °C to &lt
  • 30 °C (50 °F to 86 °F) is the 95% non-condensing range. 75%: 86 °F to 104 °F, or 30 °C to &lt
  • 40 °C Operating altitude: 6581 feet, or 2000 meters Degree of pollution: 2. IP40 classification 1.m (3.28ft) drop test Mechanisms Mechanisms Energy source: eight AA batteries Typical power consumption in High/Low mode is 70mA. 90mA in loop mode with clamp. Usage in the absence of signal transmission: 10mA Battery life: around 25 hours in high/low mode Loop mode: roughly 18 hours Fuse: Ø 6 x 32 mm, 50 kA interrupt, 1.6A, 700V fast acting Low battery warning: Indeed. Dimensions: 183 x 93 x 50 mm (7.2 x 3.66 x 1.97 in) (L x W x H) Weight: around 1.25 pounds (0.57 kg) Energy source: eight AA batteries Typical power consumption in High/Low mode is 70mA. 90mA in loop mode with clamp. Usage in the absence of signal transmission: 10mA Battery life: around 25 hours in high/low mode Loop mode: roughly 18 hours Fuse: Ø 6 x 32 mm, 50 kA interrupt, 1.6A, 700V fast acting Low battery warning: Indeed. Dimensions: 183 x 93 x 50 mm (7.2 x 3.66 x 1.97 in) (L x W x H) Weight: around 1.25 pounds (0.57 kg) Environmental Operating temperature: -20ºC to 50ºC (-4ºF to 122ºF) Operating humidity: 10 °C to &lt
  • 30 °C (95 %: 50 °F to &lt
  • 86 °F) 30 °C to &lt
  • 40 °C (75 %: 86 °F to &lt
  • 104 °F) 40 °C to &lt
  • 50 °C (45 %: 104 °F to &lt
  • 122 °F) Operating altitude: 2000m (6581ft) Pollution degree: 2 IP rating: IP40 Drop test: 1m (3.28ft) Mechanical Maximum conductor size: 32mm 91.26mm (1.26in) Dimensions (L x W x H): 150 x 70 x30mm (5.9 x 2.75 x 1.18in) Weight: Approx 0.114KG (0.25lb) 2000ACC Test Lead Accessory Kit Includes: 2 x 1m test leads (red,black) 1 x 7m test lead (green) 2 x test probes (black) 2 x alligator clips (red, black) 2 x outlet blade adaptors 2 x outlet Measurement category: CAT IV 600V (test leads), CAT II 1000V, CAT IV 600V (alligator clips) CAT II 300V (outlet adaptors) Operatomg voltage and current: 600V 10A max (red/black leads), 600V 10A max (green lead), 1000V 8A max (black probe) 600V 10A max (alligator clips), 300V 10A max (outlet adaptors) Operating temperature: 0°C to 50°C (32°F to 122°F) 0°C to &lt
  • 30°C (95%: 50°F to &lt
  • 86°F), 30°C to &lt
  • 40°C (75%: 86°F to &lt
  • 104°F) are the operating humidity ranges. 40%: 104 °F to &lt
  • 122 °F
  • 40 °C to &lt
  • 50 °C) Temperature and humidity range for storage: 0°C to 60°C (32°F to 140°F). Operating altitude: 6561 feet, or 2000 meters Degree of pollution: 2. IP20 water and dust resistance 1 meter (3.28 feet) drop proof Measurements: Leads: Green: 7m (22.97ft), Red/Black: 1m (3.28ft). approximately 95 x 45 x 24 mm (3.74 x 1.77 x 0.94 in) for alligator clips 72 x 18 x 18 mm (2.83 x 0.71 x 0.71 in) outlet adapters Weight: around 0.4 kg (0.88 lb)
  • Fluke 2052R Advanced Wire Tracer and Fluke 2000T Transmitter, both rated for CAT IV 600V safety, are included in the kit. Find cables that are both energized and de-energized. Protection against transient overvoltage spikes up to 8000V is provided by the Fluke 2052R. Find the openings, breaks, and shorts. There are four ways to operate the Fluke 2052R: Quick Scan, Accuracy, Non-contact Voltage, and Breaker The receiver'
  • s tip makes it possible to trace junction boxes, orders, and confined spaces. four AA batteries power the battery. A 2.5-inch color TFT LCD screen Three signal intensities are available with the Fluke 2000T Transmitter: High, Low, and Loop. The Fluke 2000-T transmitter will choose an output frequency of either 6 kHz or 33 kHz based on its automated perception of whether the system is powered on or off. There are eight receiver sensitivity settings that offer more accuracy and versatility when