Multiple static motor aspects can be tested with the Megger Baker MTR105 Rotating Machine Tester. The motor tester is appropriate for production testing of new motors and generators, testing of refurbished or repaired motors and generators, or in-field testing of motors and generators that are in operation due to its extensive range of test and measurement facilities. This has uses in a variety of industries, such as manufacturing, transportation, HVAC, motor maintenance, and utility companies. Advanced Motor Testing The Megger Baker MTR105 Motor Tester offers a variety of advanced tests. These consist of temperature compensation, dielectric absorption ratio, and polarization index measurement of insulation resistance from 100Ω to 200GΩ. There are test voltages available of 50V, 100V, 250V, 500V, and 1000V. Notably, a bi-directional DLRO four-wire Kelvin low resistance test function is also included for measuring resistance up to 10Ω with an accuracy of ±0.25% ± 10 digits and a resolution of 0.01mΩ.Bi-directional continuity testing (20mA or 200mA test current), capacitance (0.1nF to 1mF), three-phase AC/DC voltage measurement up to 1000V, phase rotation indication, motor rotation test, and inductance measurement (2mH to 1H) are among the additional measurement functions available on the Megger Baker MTR105. Temperature compensation is facilitated by an additional temperature measurement function that uses a type T thermocouple with a range of -20˚C to 200˚C (or up to 1000˚C with a type J or K thermocouple). Designed for Practicality The Megger MTR105 can be customized and operated with ease using a straightforward rotary dial and push-button interface. The vivid color screen, which can show both graphical and numerical representations, shows the readings. Up to 256 result sets with a time and date stamp can be stored in the motor tester's internal memory and downloaded to a PC via a USB connection. With its ample battery life, the Megger MTR105 can run 1200 insulation or continuity tests or a complete suite of tests on up to ten motors. The guard terminal stops surface leakage current, and the tester's protective design grants it an IP54 ingress protection rating. It is robust and comfortable because of the ABS housing and overmolded rubber case. Live circuit detection, which forbids risky testing, and user-adjustable lockout voltage put safety first. A hook strap, soft carry pouch, insulation resistance lead set, type T thermocouple, and Cat III 600V Kelvin lead set are included with the tester.

  • Voltages to test: 50V, 100V, 250V, 500V, and 1000V Ranges of test voltages: 10GΩ, 20GΩ, 50GΩ, 100GΩ, 200GΩ Accuracy of the test voltage: Amounts per GΩ: ±2% ± 2 digits ± 4.0%
  • ±2% ± 2 digits ± 2.0%
  • ±2% ± 2 digits ± 0.8%
  • ±2% ± 2 digits ± 0.4%
  • ±2% ± 2 digits ± 0.2% Index of polarization: 10 minutes to 1 minute Dielectric absorption ratio: 15 or 30 seconds, user-configurable start of t1 and t2 fixed at 60 seconds &lt
  • 5% error at 500kΩ parallel circuit resistance with a 100MΩ load is the guard terminal performance. 0.1kΩ resolution Current for short circuit/charge: 2 m + 0% -50% (IEC61557-92) Accuracy of terminal voltage: -0% + 2% ±2V Test current: 1 mA at least, passing the insulation value up to a maximum of 2 mA 0.10MΩ to 1.0GΩ is the operation range (IEC61557-2). Display of leakage current: 10% (±3 digits) at 0.1µA resolution Display voltage as ±3%, ±2 digits, and ±0.5% of the rated voltage. Note: The above specifications only apply when the instrument is used with high-quality silicone leads that come with it. Continuity Measurement: 0.01Ω to 1MΩ (or, on an analog scale, 0 to 1000kΩ). ±3% ± 2 digits (0 to 99.9Ω)
  • ±5% ± 2 digits (100Ω to 500kΩ) represent accuracy. 200 mA (-0 mA + 20 mA)
  • 0.01 Ω – 4 Ω is the test current. Single or dual polarity (by default in the factory) polarity Resistance to lead: null up to 10Ω Choose a current limit between 20 and 200 mA. Capacitance Range: 0.1 nF to 1 mF 5% ± 2 digits (1nF to 10µF) of accuracy Voltmeter Range: 10mV to 1000V (AC, TRMS sinusoidal 15Hz to 400Hz)
  • 0 to 1000V (DC). Precision: +/- 2% ±2 numbers (0 - 1000 V DC)
  • +/- 2% ±2 numbers (10 mV - 1000 V TRMS AC) Range of frequencies: 15–400 Hz (50 mV–1000 v). Resolution of frequency: 0.1 Hz Accuracy of frequency: ±0.5% ± 1 digit Accuracy of diode test: ±2% ± 2 digits (0.01 to 3.00V) Range of the diode test display: 0.00V to 3.00V Temperature measurement and compensation Type T thermocouple (Type K and Type J) Range of thermocouple: -20 to 200 °C (4 °F to 392 °F) Range of the instrument: -20 °C to 1000 °C (4 °F to 1832 °F). Resolution of the instrument: 0.1 °C (0.18 °F) Accuracy of the instrument: ±1.0 °C, ±20 digits (1.8 °F). (The basic accuracy mentioned assumes measurements in both directions.) DLRO four wire Kelvin low resistance Current test: 200 mA DC Range: 10 Ω to 1 mΩ 0.01 m© is the resolution. Accuracy: ± 0.25% rdg. ± 10 digits
  • both forward and reverse measurements are included in the accuracy stated. Inductance 2 mH, 20 mH, 200 mH, and 1 h Accuracy @ 1 kHz ±(1.0 % +(Lx/10000) % +5 digits) ±(0.7 % +(Lx/10000) % +5 digits) ±(0.7%) + (Lx/10000) % +5 digits @ 120 Hz ±(2.0 % + (Lx/10000) % +5 digits) @ 1 kHz Only 1.2% + (Lx/10000) % + 5 digits) @ 1 kHz and 2.0% + (Lx/10000) % + 5 digits) @ 1 kHz were measured at 120 Hz. Results storage 256 motor results with date and time stamped can be stored. USB Type A (USB Mass Storage Device) data download Power Six LR6 1.5 V Alkaline (AA) batteries, one FR6 1.5 V Lithium (LiFeS2) battery, and one HR6 1.2 V NiMH (rechargeable) battery are available. Ten motors per battery (full suite of tests at 100 V into 100 MΩ). IEC61557-2 - test cycle: 1200 insulation tests at 500 V for 25 seconds on standby, with a duty cycle of 5 s and 0.5 MΩ. IEC61557-4 test cycle: 1200 continuity tests on a 1 Ω resistance with a duty cycle of 5 seconds for testing and a 25-second standby. Battery charging: Kit for mains batteries. Protection against hazards: IEC61010-1 CAT III 600 V Industrial EMC IEC61326 Coefficient of temperature: &lt
  • 0.1% per °C up to 1 G\ Environment The operational temperature range is 14 °F to 122 °F (-10 °C to 50 °C). Range of storage temperatures: -13 °F to 149 °F (-25 °C to 65 °C) 90% relative humidity at 40 °C (104 °F) Maximum temperature for calibration: 20 °C (68 °F) 3000 meters is the highest point (9843 ft.) IP54 is the IP rating. Physical Display: Full-color LCD screen with adjustable backlight Languages spoken: Spanish, German, French, and English. Dimensions: 8.98 x 4.1 x 2.95 in. / 228 x 105 x 75 mm 1.00 kg (2.2 lbs) in weight x2 500 mA fuse (FF) 32 x 6 mm ceramic fuse, 1000 V, minimum 30 kA, high break capacity HBC. Installing glass fuses is not recommended.
  • Perfect for motor and generator testing Ideal for testing brand-new, refurbished, or operational units Complete set of Megger tests for insulation resistance Low-resistance, four-wire DLRO testing Phase-indicating voltage measurement Testing of motor rotation Testing for bidirectional continuity at 20 mA or 200 mA test current Measurements of capacitance and inductance Temperature gauge featuring a compensatory feature vivid, graphical presentation basic push-button and rotary dial interface memory that can be downloaded for 246 full test sets