With the Fluke 1587/i400 FC Insulation Multimeter Kit, users can maximize the exceptional insulation and electrical testing capabilities of the Fluke 1587 FC Insulation Multimeter and Fluke i400 AC Current Clamp, along with a few other useful accessories. The Fluke 1587 FC is the kit's primary instrument. It can measure temperature between -40˚C and 537˚C, capacitance up to 999µF, frequency up to 99.99kHz, and AC/DC voltage up to 1000V. It can also perform continuity and diode testing. Additionally, the device can measure insulation resistance using test voltages of 50V, 100V, 250V, 500V, and 1000V for a range of 0Ω to 2GΩ. The True RMS measurement for AC values is one of the additional features. The Fluke Connect App and wireless connectivity through wi-fi enable users to edit and analyze results on smart devices for speedy information organization and distribution. TrendIt graphs, temperature compensation, and PI/DAR timed ratio tests are among the options. The Fluke i400 is the second major part of the kit. The current measurement range of this safe clamp-style AC current probe is increased to 400A AC. Rated Cat IV 600V and Cat III 1000V, it has an ergonomic design that is comfortable to use. The conductor diameter is precisely and accurately measured up to a maximum of 32 mm. Two crocodile clips, two test probes, a remote probe, a type K thermocouple, and red/black test leads are among the additional accessories included in the kit. Everything is provided.
- AC voltage measurement (Range / Resolution / Accuracy 50 to 60Hz / Accuracy 60 to 5000Hz)
±(1% + 3) / 600.0 mV / 0.1 mV / ±(2% + 3)
A.V. / 0.001V / ±(1% + 3) / ±(2% + 3)
0.01V / ±(1% + 3) = 60.00V / ±(2% + 3)
Ⱡ(1% + 3) / 0.1V / 600.0V / ±(2% + 3)
(2% + 3) / ±(1000V / 1V) / ±(2% + 3)
Low-Pass Filter Voltage (Range / Resolution / Accuracy 50 to 60Hz / Accuracy 60 to 400Hz
600.0 volts / 0.1 volts / ±(1% + 3) / +(2% + 3), -(6% - 3)
0.001V / ±(1% + 3) / +(2% + 3), -(6% - 3) 6.000V
-(6% - 3) / 60.00V / 0.01V / ±(1% + 3) / +(2% + 3),
600.0 V/0.1 V / ±(1% + 3) / +(2% + 3), -(6% - 3)
-(6% - 3) / 1000V / 1V / ±(2% + 3) / +(2% + 3)
DC Voltage Measurement (Range / Resolution / Accuracy
600.0mV / 0.1mV / ±(0.01% + 1)
AC Current Measurement (45Hz to 1000Hz) (Range / Resolution / Accuracy / Burden Voltage
400mA / 0.1mA / ±(1.5% + 2)1 / 2 mv/mA
60mA / 0.01mA / ±(1.5% + 2) / 2 mV/mA
DC Current Measurement (Range / Resolution . Accuracy Burden Voltage
±(0.2% + 2) / 400 mA / 0.1 mA / 2 mv/mA
ñ(0.2% + 2) / 60 mA / 0.01 mA / 2 mV/mA
Overload: 600 mA for no more than two minutes
For mA input, the fuse protection is 0.44mA, 1000V, IR 10kA.
AC conversion: The 11 kHz bandwidth inputs are AC-coupled and calibrated to the sine wave input'
- s RMS value.
Resistance measurement (Range / Resolution / Accuracy
600.0Ω /±(0.9% + 2)· / 0.1Ω
6.000kΩ/±(0.9% + 2) / 0.001kΩ
0.01kΩ / ±(0.9% + 2) = 60.00kΩ
0.1kΩ / 600.0kΩ / ±(0.9% + 2)
Six Thousand MΩ / 0.001 MΩ / ±(0.9% + 2)
±(1.5% + 3) / 50.0MΩ2 / 0.01MΩ
Protection against overload: 1000V DC or RMS
Minimum open circuit voltage (DC) of 8.0V, minimum short circuit current of 1.1mA
1 The accuracy ranges from 0% to 100%.
2As much as 80% RH
Diode Test
Diode test indication: Display voltage drop 0.6V at 1mA nominal test current
Accuracy: ±(2% + 3)
Continuity Test
Constant buzzer for resistance below 25Ω and off for resistance above 100Ω (maximum reading = 1000Ω) indicates continuity.
8.0V is the open circuit voltage.
Current on short circuit: 1.0 mA Typical 1000V RMS overload protection
Time of response: greater than one millisecond
Frequency Measurement (Range / Resolution / Accuracy)
0.01 Hz / ±(0.1% + 1) = 99.99 Hz
(0.1% + 1) / 0.1Hz / 999.9Hz
0.001kHz / 9.999kHz / ±(0.1% + 1)
0.01 kHz / 99.99 kHz / ±(0.1% + 1)
Frequency Counter Sensitivity (Voltage / V AC sensitivity (RMS Sine Wave)1 5Hz to 100kHz / DC trigger levels1 to 20kHz2
100 mV, 150 mV, 600 mV AC, and n/a
60V, 10V, 36V, 1.2V, and 4.0V
- 6V, 1V, 1.5V, -400.0mV, and 2.5V
12V, 40V, 100V, n/a, and 600V
12V, 40V, n/a, 300V, and 1000V
For a given accuracy, enter 1 mA plus 10 x range (maximum 1000 V). Accuracy may be impacted by low frequency and amplitude noise.
2Usable with full scale input up to 100 kHz
Capacitance Measurement (Range / Resolution / Accuracy)
±(1.2% + 2) / 1000nF / 1nF
0.01µF / ±(1.2% + 2) = 10.00µF
12.1 percent ± 90 counts = 100.0µF / 0.1µF / ±
1µF / ±(1.2% ± 90 counts) = 9999µF
Temperature Measurement (Range / Resolution / Accuracy)
-40°C to 537°C / 0.1°C / ±(1% + 10)
1Accuracies apply following 90 minutes settling time after a change in the ambient temperature of the instrument
Insulation Specifications
Range of measurement: 0.01MΩ to 2GΩ
Test voltages: 1000, 1000V, 500V, 250V, and 100V
Accuracy of test voltage: +20%, -0%
Test current for short circuits: nominally 1 mA
Auto discharge: Duration of discharge
Live circuit detection: Before the test is started, stop it if the terminal voltage is higher than 30 volts.
Maximum load capacity: able to function at up to 1µF load
Output Voltage (Test Voltage / Display Range / Resolution / Test Current 1 / Accuracy 1 / Display Range 2 / Resolution 2 / Test Current 2 / Accuracy 2 / Display Range 3 / Resolution 3 / Test Current 3 / Accuracy 3)
50V (0%–20%), 0.01–6MΩ, 0.01MΩ, 1mA @ 50kΩ, ±(3% + 5) and 6–50MΩ, 0.1MΩ, 1mA @ 50kΩ, ±(3% + 5) / - / - / - / 0.01 to 6MΩ / 0.01MΩ / 1mA @ 100kΩ / ±(3% + 5) / 6 to 60MΩ / 0.1MΩ / 1mA @ 100kΩ / ±(3% + 5) 250V (0% to +20%) / 60 to 100MΩ / 1MΩ / 1mA @ 250kΩ / ±(1.5% + 5) / 0.1 to 60MΩ / 0.1MΩ / 1mA @ 250kΩ / ±(1.5% + 5) / 60 to 250MΩ / 1MΩ / 1mA @ 250kΩ / ±(1.5% + 5) / - / - / - / - 500V (0% to +20%) / 0.1 to 60MΩ / 0.1MΩ / 1mA @ 500kΩ / ±(1.5% + 5) / 60 to 500MΩ / 1MΩ / 1mA @ 500kΩ / ±(1.5% + 5) / - / - / - / - 1000V (0% to +20%) / 0.1 to 60MΩ / 0.1MΩ / 1mA @ 1MΩ / ±(1.5% + 5) / 60 to 600MΩ / 1MΩ / 1mA @ 1MΩ / ±(1.5% + 5) / 0.6 to 2.0GΩ / 100MΩ / 1mA @ 1MΩ / ±(10% + 3)
General
Maximum voltage of 1000V
Cold storage (-40°C to 60°C)
Comfort range for operation: -20°C to 55°C
Temperature coefficient: for temperatures below 18 °C or above 28 °C, 0.05 x (with specified accuracy) per °C
0% to 95% at 10 °C to 30 °C
- 0% to 75% at 30 °C to 40 °C
- and 0% to 40% at 40 °C to 55 °C are the relative humidity of non-condensing materials.
Random, 2g, 5-500Hz per MIL-PRF-28800F, Class 2 vibration
2.4 GHz ISM Band radio frequency communication
Radio frequency certification: IEC 61010-2-033: Cat IV 600V / Cat III 1000V
- FCC: T68-FBLE
- IC: 6627A-FBLE
- IEC 61010-1: Pollution degree 2
Four AA batteries (NEDA 15A or IEC LR6) are needed.
1000 hours of battery life
- Fluke Insulation Multimeter 1587 FC
i400 AC Current Clamp Fluke
lead testers for tests
Two crocodile clips
Two test probes
One remote probe
hefty carry case
CD with instructions