Fluke 1577 Insulation Multimeter

Fluke 1577 Insulation Multimeter

GBP £ 618.00

Manufacturer: Fluke

Fluke 1577 Insulation Multimeter With full True-RMS digital multimeter functionality, the Fluke 1577 Insulation Multimeter is a portable digital insulation tester. Insulation can be tested between 0.1 and 600 MΩ, and voltage can be tested between 500 and 1000 V. Because live circuit detection is in place, if voltage greater than 30V is detected, the test cannot proceed. For added security, auto-discharge capacitive voltage is also provided. The Fluke 1577 is a portable multimeter that can measure resistance, continuity, AC/DC voltage, DC millivolts, and AC/DC current. The Fluke 1577 offers users flexibility for troubleshooting and maintenance in a single, portable tool. Easy testing selection is made possible by the rotary dial and backlit LCD screen. With a meter battery life of 1000 hours and 1000 insulation tests, as well as safety ratings of VAT IV 600V and CAT III 1000V, users can be sure they are safe and can perform numerous tests without having to constantly change the unit's batteries

  • Voltage DC Maximum Voltage: 1000 volts Precision: ±(0.2%+2) Resolution maximum: 0.001V Voltage AC Maximum Voltage: 1000 volts Precision: ±(2%+3) Resolution maximum: 0.1 mV Current DC 400mA is the maximum amps. Accuracy of Amps: ±(2%+2) 0.01 mA at maximum resolution Current AC The maximum amps is 400mA. Amp accuracy: ±(2%+2) At maximum resolution, 0.01 mA Resistance Höchst Widerstand: 50 MΩ Precision: ±(2%+3) Maximum depth of focus: 0.1 Ω Insulation Test Test current minimum at 1kΩ/V: 1mA 500 volts and 1000 volts for testing Maximum resistances for each test voltage are 0.1 MΩ/1000 V. Maximum resolution per test voltage: 50V: 0.01MΩ 0.01MΩ at 100V 250V: 0.1MΩ 500V: 0.1MΩ 0.1MΩ at 1000V Accuarcy per test voltage: 50V: ±(3% + 5) 100V: ±(3% + 5) 250V: ±(1.5% + 5) 500V: ±(2% + 5) Environmental Specifications: Temperature range for operation: -20 to 55 Cold storage (-40°C to 60°C) (without condensation) Humidity range: 0%–95% (10°C–30°C) 0%-40% (40°C – 55°C), 0%-75% (30°C–40°C). Altitude of operation: 2000 meters Safety Specifications: Pollution Degree 2 Measurement: IEC 61010-2-033: CAT IV 600V / CAT III 1000V General: IEC 61010-1 Environmental Specifications 203 x 100 x 50 mm in size (holster included) 624g in weight Three-year warranty Alkaline battery life: Use of the meter: 1000 hours Life of the battery Use of insulation tests: one thousand tests. (Normal tests with a duty cycle of five seconds on and twenty-five seconds off, measuring 1000V into 1MΩ IP40 classification
  • Test voltages for insulation: 500V and 1000V Test for insulation: 0.1 MΩ to 600 MΩ Automatic capacitive voltage discharge DC/AC Voltager milliamperes DC Testing for resistance (0.1Ω to 50MΩ) Testing for continuity Alligator clips, test leads, and a remote probe dependable, functional hard case Automatic shut-off to conserve battery life Real-RMS a sizable backlit display For additional user protection, live circuit detection stops the insulation test if voltage greater than 30 V is detected. Three-year warranty for safety rated CAT III 1000V and CAT IV 600V.