Fluke 1503 Insulation Resistance Tester

Fluke 1503 Insulation Resistance Tester

GBP £ 386.40

Manufacturer: Fluke

With a measurement range of 0.1MΩ to 2000MΩ, the Fluke 1503 Insulation Tester is a useful and trustworthy insulation tester. The user has a choice between two test voltages of 500V and 1000V for measuring insulation resistance, and clear images of insulation and system performance are provided by earth bond resistance testing, continuity testing, and AC/DC voltage measurement up to 600V. A variety of add-ons enable the user to fully utilize the Fluke 1503's measurement features. Test leads, test probes, and crocodile clips are included with the product as standard. The integrated test button on the remote probe helps the user take repeated readings or attempt testing in inaccessible areas. The Fluke 1503's backlit LCD screen displays results, and its four AA batteries provide enough power for at least 1000 insulation tests. At only 550g, the device is lightweight and portable, making it suitable for use in both dimly lit areas and large areas. The large test button and straightforward dial interface make operation very simple. The outstanding safety credentials of the Fluke 1503 are a result of several factors. When a pre-existing voltage of more than 30V is detected, insulation testing is halted and the capactive voltage is automatically discharged to protect the user from dangerous voltage levels. Additional peace of mind is offered by the inputs' Cat IV rating up to 600V.

  • AC/DC Voltage measurement 600.0V is the range 0.1V is the resolution. Accuracy: 50 to 400Hz ±(2% + 3) Protection against overload: 600V AC or DC Earth bond resistance measurement Range: 200Ω, 2000Ω, 20kΩ, and 20Ω Resolution: 0.1Ω, 1Ω, 0.01kΩ, and 0.01Ω Precision: ±(1.5% + 3) Test voltage for an open circuit: &gt
  • 4.0V, &lt
  • 8V &gt
  • 200mA for the short circuit current Insulation Resistance span: 0.1MΩ–2000MΩ 500V DC and 1000V DC test voltages Accuracy of test voltage: +20%, -0% Nominal short circuit current: 1 mA Automatic discharge: Time of discharge &lt
  • 0.5s for C + 1µF Indicator for live circuit: If terminal voltage is greater than 30 volts before initialization, inhibit the test. Maximum load capacity: able to function at up to 1µF load ±(1.5% + 5) 500V, ±(1.5% + 5) 1000V, ±(1.5% + 5) up to 2000MΩ, and ±(10% + 3) over 2000MΩ are the measurement accuracy ranges. General Maximum voltage: DC or AC 600V Temperature range for storage: -40˚ to 60˚C Comfort range for operation: -20°C to 55°C Temperature coefficient: when &lt
  • 18˚C or &gt
  • 28˚C, 0.05 x (with specified accuracy) per ˚C At 10 °C to 30 °C (50 °F to 86 °F), 0 % to 75% @ 30 °C to 40 °C (86 °F to 104 °F), and 0 % to 40% @ 40 °C to 55 °C (104 °F to 131 °F) are the relative humidity ranges. Vibration: Class 2 instrument, random, 2g, 5-500Hz per MIL-PRF-28800F Shock: a one-meter drop Safety: Conforms to IEC/EN 61010-1, Second Edition, CAN/CSA-C22.2 NO. 61010-1-04, and ANSI/ISA 82.02.01 (61010-1) 2004 for measurement category IV 600 V (CAT IV). Included are four AA batteries. Battery life: &gt
  • 2500 earth bond resistance tests, &gt
  • 1000 high voltage tests Measuring 50 by 100 by 203 mm 550g in weight IP40 classification Operating elevation: 2000 meters
  • Storage elevation: 12000 meters.
  • Range of insulation resistance: 0.1MΩ–2000MΩ 500V and 1000V test voltages Earth bond resistance testing Testing for continuity and measuring AC/DC voltage up to 600V Standard supplies include a remote probe, test probes, test leads, and crocodile clips. digital screen with backlighting Over 1000 tests are powered by 4 AA batteries. Basic dial interface with LED warning of potentially hazardous voltage When voltage is detected to be less than 30V, insulation tests are stopped. Automatic capacitive voltage discharge