For measuring insulation on phone lines, the Chauvin Arnoux CA6532 Telecommunications Insulation Tester is perfect because it was created especially for the telecom sector. Test voltages of 50V or 100V are available, enabling high-resolution measurements of up to 20GΩ of insulation resistance. Leakage current measurement is a crucial component of the tester, and it can be configured to run on a timer. Furthermore, resistance quality can be evaluated without temperature-related error by calculating the PI/DAR ratio. The Chauvin Arnoux CA6532 is the best instrument for examining phone cables because of its many sophisticated measurement features. Measurements of voltage, regular resistance, capacitance, frequency, and continuity testing at 20 and 200 milliamperes are among the functions of multimeters. Comparing two wires' resistance using relative mode is possible, but linear capacitance Despite its many features, the Chauvin Arnoux CA6532 is incredibly easy to operate thanks to a straightforward dial and push-button interface in addition to a magnetic mount. Results are shown simply and clearly on the bright, backlit screen, which also features an analogue bar graph for more nuance. The megohmmeter has an internal memory that can store up to 1300 readings, which can subsequently be downloaded to a smart device via Bluetooth. Afterwards, analysis can be performed using the optional Chauvin Arnoux DataView program. The Chauvin Arnoux CA6532 comes with a number of accessories, and its sturdy design makes it perfect for field use. The instrument has a two-year warranty and is safety rated Cat IV 600V.
- Voltage
Resolution / Measurement range: 0.3 V to 399.9 V / 0,1 V
- 400 V to 700 V / 1 V
Accuracy / Input impedance: 400 kΩ / ± (3 % + 2 cts)
15.3–800 Hz is the DC operating frequency.
Frequency
Measurement range / Resolution / Accuracy: 15.3 Hz-399.9 Hz / 0.1 Hz / ± (1 % + 2 cts)
- 400-800 Hz / 1 Hz / ± (1 % + 1 ct)
Insulation
Test voltage range: 50–100 V
Maximum test voltage range: 20 GΩ
Respect for the IEC 61557-2 standard: Two G
10 kΩ–10 GΩ is the measurement range at 50V.
20 kΩ–20 GΩ is the measurement range at 100V.
10(1)-999 kΩ and 1.000-3.999 MΩ / 1 kΩ
- 4.00 - 39.99 MΩ / 10 kΩ
- 40.0-399.9 MΩ / 100 kΩ
- 400 - 3,999 MΩ / 1 MΩ
- 4.00 - 39.99 GΩ / 10 MΩ
- 40.0 - 200 GΩ / 100 MΩ are the measurement range and resolution.
Precision: ± (3% + 2 cts)
Test voltage: -0% + 20% (I <
- 1 mA)
Test voltage display: ± (3 % + 3 cts)
Test current and resolution displayed: 0.01 µA - 39.99 µA / 10 nA
- 40.0 -399.9 µA / 100 nA
- 0.400 -2.000 mA / 1 µA
Test current accuracy: ± (10% + 3 cts)
Ratios of PI to DAR: 10 / 1 - 1 / 30 s
Timer (minutes: seconds):
Continuity
The continuity measurement range is as follows: 0.0 – 100.0 Ω (20 mA)
- 0.00 Ω–10.00 Ω (200 mA).
Precision / Voltage of the open circuit: ± (2 % + 2 cts) / ≥ 6 V
Current used for measurement: 20 mA range: 20 mA ± 5 mA
- 200 mA range: 200 mA (-0 mA + 20 mA).
Continuity thresholds (2 Ω, 1 Ω, programmable threshold) for the rapid beep
Cable compensation: up to 9.99 Ω
Resistance
0 -3,999 Ω / 1 Ω
- 4.00 kΩ - 39.99 kΩ / 10 Ω / ± (3 % + 2 cts)
- 40.0 kΩ - 399.9 kΩ / 100 Ω
- 400 kΩ-1,000 kΩ / 1 kΩ / ± (3 % + 2 cts)
Capacitance
0.1 nF – 399.9 nF / 0.1 nF
- 400 nF – 3,999 nF / 1 nF
- 4.00 µF – 10.0 µF / 10 nF are the measurement range and resolution.
Precision: ± (3% + 2 cts)
Distance on line: 0–100 km
General specifications
Display: logarithmic bargraph plus two x 4,000 cts
300 measurements are stored.
Power supply/autonomous shutdown: six LR6 (AA) batteries /deactivatable, five minutes
Life of battery: 1,500, 2,500, 6,000 measurements: 3,000 continuity measurements (5 s ON / 55 s OFF)
- UN x 1 kΩ @ UN.
Dimensions: 211 x 108 x 60 mm / 850 g / IP 54 / IK 04
- weight
- dimensions (h x w x d)
-
IEC 61326-1, IEC 61010-1, and IEC 61010-2-030, 600 V CAT IV, EMC and electrical safety
Standards compliance: IEC 61557 parts 1, 2, 4, and 10
Two-year warranty
- Range of insulation resistance: 20GΩ
50V and 100V test voltages
Resistance and continuity testing
Measurements of leakage current and the PI/DAR ratio
Tests with adjustable times and alarms
Measurements of voltage, frequency, and capacitance
Measurement of linear capacitance
Calculating the cable length
Mode of comparison relative to wires
Internal storage for a maximum of 1300 outcomes
Bluetooth connectivity Cat IV 600V
Two-year guarantee