The purpose of the Chauvin Arnoux CA6011 Continuity Tester is to test the protective earth conductors of appliances, electrical equipment, and new equipment installations. In compliance with the relevant laws, the CA6011 permits a user-defined programmable continuity threshold (1 Ω or 2 Ω) and measures continuity (up to 20 Ω) or resistance (up to 200 Ω). With its two-color backlighting and 2,000 count display, the CA6011 can measure up to 30,000 in real-world scenarios or 4,500 according to the IEC 61557-4 protocol before the batteries need to be changed. With just four buttons on the front panel, the CA6011 offers a straightforward user interface that allows you to access all of its functions right away. The operator's safety is ensured by visual and audible (red/blue screens) alarms in the event that voltage is detected, adhering to IEC 61557-4, 300V Cat IV, and IEC 61010 safety standards.
- Continuity
Range of Measurement: 0.00Ω to 2.00Ω/2.00Ω to 20.00Ω
10 m© is the resolution.
Current of Measurement: 200 mA/20 mA
Voltage in the open circuit: ±(4 VDC <
- U <
- 6 VDC)
Resistance
Range of Measurement: 1.0Ω to 200.0Ω
100m© is the resolution.
Current of measurement: 10 mA
Range of the open circuit: ±(4 VDC <
- U <
- 6 VDC)
Continuity threshold: Programmable 1Ω ru 2Ω
Compensation of cable resistance: Yes, <
- 5Ω
Indication of test compliance/non compliance: Visual and or audible and/or vibrating, configurable/h4>
-
Standards met: IEC 61010-1, IEC 61010-2-030 300 V CAT IV, IEC 61557-1 &
- IEC 61557-4
Ten minutes of automatic standby that can be disabled
Battery life: 30,000 tests under actual operating circumstances 4,500 according to protocol IEC 61557-4
Presence of voltage: audible and visual
Four standard power supplies AA/LR6 1.5V batteries
Measurements (reeling box + instrument): 225 x 185 x 135 mm
- Weight (CA6011 only): 350g
- Measurements that meet IEC 61557-4 requirements
Measurement range for continuity: 0.00 Ω to 20.00 Ω
Autonomous reversal of polarity
200 mA measurement current
Adjustment of the measuring leads'
- resistance
Measurement of resistance: up to 200.0Ω
Conformance threshold programmable at <
- 1Ω or <
- 2Ω
Dual-color backlit display
Measurements can be made up to 30,000 times before a new battery is needed.
complies with IEC 61557-4, 300V Cat IV, and IEC 61010 safety requirements.