Fluke 1664FC Multifunction EVSE Test Kit

Fluke 1664FC Multifunction EVSE Test Kit

GBP £ 2,039.69

Manufacturer: Fluke

Using the Fluke 1664FC Multifunction Tester and the Fluke FEV300 EV Charging Station Test Adaptor with Type 2 Connector, the Fluke 1664FC Multifunction EVSE Test Kit evaluates the performance and security of electric vehicle charging stations. Tester Fluke 1664FC Multifunction The 1664FC Fluke EV charging station DC protection devices can be tested using the RCD type B (smooth DC Currents) VAR mode when used with an adaptor like the Fluke FEV300. The test currents for RCD type A-EV or RDC-DD acc can be tested with this generator in accordance with IEC 62955 safety regulations (6/60/200 mA and ramp 2 to 6 mA ramp). This enables quick and simple further testing of 6mA DC RCD monitors on charging points by the operator. A safe and effective electrical testing device is the Fluke 1664, which can perform a variety of tests including those for True-RMS AC voltage, resistance, loop and line impedance, tripping speed, potential earth fault current, earth resistance and RCD/FI tripping current. With CAT III 500V over voltage protection and an earth voltage touchpad that can identify elevated earth voltages (>50V), potentially hazardous test conditions are highlighted. The Fluke 1664 is compatible with Fluke Connect technology, which enables users to stream test results directly to a smart device, and Fluke Cloud database, which stores test results and allows for instant sharing with clients or coworkers. The Fluke 1664FC is an accurate and safe electrical testing instrument for testing electrical systems because of its big LCD display and numerous time-saving functions, including auto-testing for line impedance, RCD trigger test, and insulation tests.

  • measurement of AC voltage:- Range:500 volts 1V as the resolution Accuracy from 45 to 66 Hz: 0.8% + 3 counts 360kΩ input impedance 660V rms overload protection RLO continuity testing Range (autoranging): 20 cents, 200 cents, and 2000 cents Resolutions of 0.01Ω, 0.1Ω, and 1Ω Voltage of an open circuit: &gt
  • 4V General:- Size: 10 x 25 x 12.5 cm (L x W x H). Weight (batteries included): 1.3 kg IP-40 Sealing Cat III to 500V
  • Cat IV to 300V of excess voltage Safety: Meets with the demands of EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA -s82.02.01 2000, and CAN/CSA c22.2 No. 1010 2nd edition. Performance: Second Editions of EN61557-1 to EN61557-7 and EN61557-10 6 x AA batteries measuring insulation resistance:- Test voltages: 50, 100, 250, 500, and 1000V tTest voltage accuracy (at the specified test current): +10%, -0% Ranges of insulation resistance: 20 to 50 MΩ, 20 to 100 MΩ, 20 to 200 MΩ, 20 to 200 MΩ, and 20 to 200 MΩ. Resolution: 0.01MΩ / 0.1MΩ
  • 0.01MΩ / 0.1MΩ
  • 0.01MΩ / 0.1MΩ
  • 0.01MΩ / 0.1MΩ / 1MΩ
  • 0.01MΩ / 0.1MΩ / 1MΩ Test currents of 1mA at 50kΩ
  • 1mA at 100kΩ
  • 1mA at 250kΩ
  • 1mA at 500kΩ
  • 1mA at 1MΩ Impedance of loops and lines (ZI):- High current mΩ mode
  • range: 10Ω
  • 0.001Ω
  • Resolutions of 0.01Ω, 0.1Ω, and 1Ω PSC test for prospective earth fault current:- 1000A to 10kA (50kA) range 1A/0.1kA resolution By dividing the actual mains voltage by the measured loop (L-PE) resistance or line (L-N) resistance, respectively, prospective earth fault current (PEFC) or prospective short current (PSC) are determined. RCD testing and varieties of RCD testing:- Type of RCD: A4, AC1, G2, S3 Notes: (1) Reacted to AC, (2) In general no delay, (3) Time delay, and (4) Reacted to pulsed signal Measurement of RCD/FI-Tripping Current and Ramp Testing (IΔN):- 30% to 110% of the RCD-rated current is the current range. 10% of IΔN2 as a step size Dwell time: Type G: 300 ms
  • Type S: 500 ms ±5%5% accuracy in measurements Trip current ranges that have been specified (EN 61008-1) are as follows: 50% to 100% for Type AC, 35% to 140% for Type A (&gt
  • 10 mA), 35% to 200% for Type A (≤10 mA), 50% to 200% for Type B, and ²5% for Type B. Notes: For Type A IΔN &gt
  • 10 mA, ¹30% to 150%
  • for Type A IΔN = 10 mA, 30% to 210%
  • for Type B, 20% to 210%. Testing the tripping speed (T):- Current settings1: 10-30-100-300-500-1000mA - VAR
  • 10-30-100mA A multiplier of 0.5, 1, and 5 Measurement of AC voltage:- Range:500 volts 1V as the resolution Accuracy from 45 to 66 Hz: 0.8% + 3 counts 360kΩ input impedance 660V rms overload protection RLO continuity testing Range (autoranging): 20 cents, 200 cents, and 2000 cents Resolutions of 0.01Ω, 0.1Ω, and 1Ω Voltage of an open circuit: &gt
  • 4V Test for Earth Resistance (RE) Range: 200Ω / 2000Ω 0.1 / 1 resolution the frequency 128 Hz. Voltage at output: 25V Connect Fluke:- Operating systems iOS 8 and later or Android 4.4 and later support Fluke Connect. General:- Size: 10 x 25 x 12.5 cm (L x W x H). Weight (batteries included): 1.3 kg IP-40 Sealing Cat III to 500V
  • Cat IV to 300V of excess voltage Safety: Meets with the demands of EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA -s82.02.01 2000, and CAN/CSA c22.2 No. 1010 2nd edition. Performance: Second Editions of EN61557-1 to EN61557-7 and EN61557-10 6 x AA batteries Measuring insulation resistance:- Test voltages: 50, 100, 250, 500, and 1000V tTest voltage accuracy (at the specified test current): +10%, -0% Ranges of insulation resistance: 20 to 50 MΩ, 20 to 100 MΩ, 20 to 200 MΩ, 20 to 200 MΩ, and 20 to 200 MΩ. Resolution: 0.01MΩ / 0.1MΩ
  • 0.01MΩ / 0.1MΩ
  • 0.01MΩ / 0.1MΩ
  • 0.01MΩ / 0.1MΩ / 1MΩ
  • 0.01MΩ / 0.1MΩ / 1MΩ Test currents of 1mA at 50kΩ
  • 1mA at 100kΩ
  • 1mA at 250kΩ
  • 1mA at 500kΩ
  • 1mA at 1MΩ Impedance of loops and lines (ZI):- High current mΩ mode
  • range: 10Ω
  • 0.001Ω
  • Resolutions of 0.01Ω, 0.1Ω, and 1Ω PSC test for prospective earth fault current:- 1000A to 10kA (50kA) range 1A/0.1kA resolution By dividing the actual mains voltage by the measured loop (L-PE) resistance or line (L-N) resistance, respectively, prospective earth fault current (PEFC) or prospective short current (PSC) are determined. RCD testing and varieties of RCD testing:- RCD type: G2, S3, AC1, Model 1664: A, AC, B5, S Notes: (1) Reacted to AC, (2) In general no delay, (3) Time delay, and (4) Reacted to pulsed signal
  • (5) Responds to smooth DC signal. Measurement of RCD/FI-Tripping Current and Ramp Testing (IΔN):- 30% to 110% of the RCD-rated current is the current range. 10% of IΔN2 as a step size Dwell time: Type G: 300 ms
  • Type S: 500 ms ±5%5% accuracy in measurements Trip current ranges that have been specified (EN 61008-1) are as follows: 50% to 100% for Type AC, 35% to 140% for Type A (&gt
  • 10 mA), 35% to 200% for Type A (≤10 mA), 50% to 200% for Type B, and ²5% for Type B. Notes: For Type A IΔN &gt
  • 10 mA, ¹30% to 150%
  • for Type A IΔN = 10 mA, 30% to 210%
  • for Type B, 20% to 210%. Testing the tripping speed (T):- Current settings1: 10-30-100-300-500-1000mA - VAR
  • 10-30-100mA A multiplier of 0.5, 1, and 5 Specifications for the Fluke 1663 Multifunction Tester Measurement of AC voltage:- 500 volts Range 1V as the resolution Precision from 45 to 66 Hz: 0.8% plus 3 counts 360 k input impedance 660V rms overload protection RLO continuity testing:- Range: 20 cents, 200 cents, and 2000 cents Resolutions of 0.01, 0.1, and 1 Voltage of an open circuit: &gt
  • 4V Test for Earth Resistance (RE):- Range: 200Ω / 2000Ω 0.1 / 1 resolution the frequency 128 Hz. General:- Size: 10 x 25 x 12.5 cm (L x W x H). Batteries: 6 x AA Weight (with batteries): 1.3 kg IP-40 Sealing Safety: Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA -s82.02.01 2000, and CAN/CSA c22.2 No. 1010 second edition regulations. Cat III to 500V
  • Cat IV to 300V of excess voltage Performance: Second Editions of EN61557-1 through EN61557-7 and EN61557-10 Measuring Insulation Resistance:- Test voltages: 50, 100, 250, 500, and 1000V Test voltage accuracy (at the specified test current): +10%, -0% Test voltage: 50, 100, 250, 500, and 1000 volts. Ranges of insulation resistance: 20 to 50 M, 20 to 100 M, 20 to 200 M, 20 to 200 M, and 20 to 200 M. Resolution: 0.01M/0.1M, 0.01M/0.1M, 0.01M/0.1M, 0.01M/0.1M/1M, and 0.01M/0.1M/1M Test currents of 1 mA at 50 k, 100 k, 250 k, 500 k, and 1 mA at 1 m Impedance of loops and lines (ZI):- High current mΩ mode
  • range: 10
  • 0.001
  • Resolution of 0.01, 0.1, and 1 RCD testing and kinds of RCD testing:- RCD type: G2, S3, AC1, Model 1663: G2, S3, A4, AC1, Reactions to AC, general no delay, time delay, and pulsed signal are noted. Measurement of RCD/FI-Tripping Current and Ramp Testing (I-N):- 30% to 110% of the RCD-rated current is the current range. 10% of IN2 as a step size Dwell time: Type G: 300 ms
  • Type S: 500 ms Measurement precision: 5% Trip current ranges that have been specified (EN 61008-1) are as follows: 50% to 100% for Type AC, 35% to 140% for Type A (&gt
  • 10 mA), 35% to 200% for Type A (10 mA), 50% to 200% for Type B, and 25% for Type B. Notes: For Type A IN &gt
  • 10 mA, 130% to 150%
  • for Type A IN = 10 mA, 30% to 210%
  • for Type B, 20% to 210%. Test of tripping speed (T):- Settings as of right now1: 10-30-100-300-500-1000mA - VAR
  • 10-30-100mA A multiplier of 0.5, 1, and 5 Range of measurements: 510ms, 160ms (RCD Type)
  • 310ms, 50ms (RCD Type G). Measurement of AC voltage:- Range:500 volts 1V as the resolution Accuracy from 45 to 66 Hz: 0.8% + 3 counts 360kΩ input impedance 660V rms overload protection RLO continuity testing Range (autoranging): 20 cents, 200 cents, and 2000 cents Resolutions of 0.01Ω, 0.1Ω, and 1Ω Voltage of an open circuit: &gt
  • 4V Test for Earth Resistance (RE) Range: 200Ω / 2000Ω 0.1 / 1 resolution the frequency 128 Hz. Voltage at output: 25V Connect Fluke:- Operating systems iOS 8 and later or Android 4.4 and later support Fluke Connect. General:- Size: 10 x 25 x 12.5 cm (L x W x H). Weight (batteries included): 1.3 kg IP-40 Sealing Cat III to 500V
  • Cat IV to 300V of excess voltage Safety: Meets with the demands of EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA -s82.02.01 2000, and CAN/CSA c22.2 No. 1010 2nd edition. Performance: Second Editions of EN61557-1 to EN61557-7 and EN61557-10 6 x AA batteries Measuring insulation resistance:- Test voltages: 50, 100, 250, 500, and 1000V tTest voltage accuracy (at the specified test current): +10%, -0% Ranges of insulation resistance: 20 to 50 MΩ, 20 to 100 MΩ, 20 to 200 MΩ, 20 to 200 MΩ, and 20 to 200 MΩ. Resolution: 0.01MΩ / 0.1MΩ
  • 0.01MΩ / 0.1MΩ
  • 0.01MΩ / 0.1MΩ
  • 0.01MΩ / 0.1MΩ / 1MΩ
  • 0.01MΩ / 0.1MΩ / 1MΩ Test currents of 1mA at 50kΩ
  • 1mA at 100kΩ
  • 1mA at 250kΩ
  • 1mA at 500kΩ
  • 1mA at 1MΩ Impedance of loops and lines (ZI):- High current mΩ mode
  • range: 10Ω
  • 0.001Ω
  • Resolutions of 0.01Ω, 0.1Ω, and 1Ω PSC test for prospective earth fault current:- 1000A to 10kA (50kA) range 1A/0.1kA resolution By dividing the actual mains voltage by the measured loop (L-PE) resistance or line (L-N) resistance, respectively, prospective earth fault current (PEFC) or prospective short current (PSC) are determined. RCD testing and varieties of RCD testing:- RCD type: G2, S3, AC1, Model 1664: A, AC, B5, S Notes: (1) Reacted to AC, (2) In general no delay, (3) Time delay, and (4) Reacted to pulsed signal
  • (5) Responds to smooth DC signal. Measurement of RCD/FI-Tripping Current and Ramp Testing (IΔN):- 30% to 110% of the RCD-rated current is the current range. 10% of IΔN2 as a step size Dwell time: Type G: 300 ms
  • Type S: 500 ms ±5%5% accuracy in measurements Trip current ranges that have been specified (EN 61008-1) are as follows: 50% to 100% for Type AC, 35% to 140% for Type A (&gt
  • 10 mA), 35% to 200% for Type A (≤10 mA), 50% to 200% for Type B, and ²5% for Type B. Notes: For Type A IΔN &gt
  • 10 mA, ¹30% to 150%
  • for Type A IΔN = 10 mA, 30% to 210%
  • for Type B, 20% to 210%. Testing the tripping speed (T):- Current settings1: 10-30-100-300-500-1000mA - VAR
  • 10-30-100mA A multiplier of 0.5, 1, and 5 Specifications for the Fluke 1663 Multifunction Tester Measurement of AC voltage:- 500 volts Range 1V as the resolution Precision from 45 to 66 Hz: 0.8% plus 3 counts 360 k input impedance 660V rms overload protection RLO continuity testing:- Range: 20 cents, 200 cents, and 2000 cents Resolutions of 0.01, 0.1, and 1 Voltage of an open circuit: &gt
  • 4V Test for Earth Resistance (RE):- Range: 200Ω / 2000Ω 0.1 / 1 resolution the frequency 128 Hz. General:- Size: 10 x 25 x 12.5 cm (L x W x H). Batteries: 6 x AA Weight (with batteries): 1.3 kg IP-40 Sealing Safety: Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA -s82.02.01 2000, and CAN/CSA c22.2 No. 1010 second edition regulations. Cat III to 500V
  • Cat IV to 300V of excess voltage Performance: Second Editions of EN61557-1 through EN61557-7 and EN61557-10 Measuring Insulation Resistance:- Test voltages: 50, 100, 250, 500, and 1000V Test voltage accuracy (at the specified test current): +10%, -0% Test voltage: 50, 100, 250, 500, and 1000 volts. Ranges of insulation resistance: 20 to 50 M, 20 to 100 M, 20 to 200 M, 20 to 200 M, and 20 to 200 M. Resolution: 0.01M/0.1M, 0.01M/0.1M, 0.01M/0.1M, 0.01M/0.1M/1M, and 0.01M/0.1M/1M Test currents of 1 mA at 50 k, 100 k, 250 k, 500 k, and 1 mA at 1 m Impedance of loops and lines (ZI):- High current mΩ mode
  • range: 10
  • 0.001
  • Resolution of 0.01, 0.1, and 1 RCD testing and kinds of RCD testing:- RCD type: G2, S3, AC1, Model 1663: G2, S3, A4, AC1, Reactions to AC, general no delay, time delay, and pulsed signal are noted. Measurement of RCD/FI-Tripping Current and Ramp Testing (I-N):- 30% to 110% of the RCD-rated current is the current range. 10% of IN2 as a step size Dwell time: Type G: 300 ms
  • Type S: 500 ms Measurement precision: 5% Trip current ranges that have been specified (EN 61008-1) are as follows: 50% to 100% for Type AC, 35% to 140% for Type A (&gt
  • 10 mA), 35% to 200% for Type A (10 mA), 50% to 200% for Type B, and 25% for Type B. Notes: For Type A IN &gt
  • 10 mA, 130% to 150%
  • for Type A IN = 10 mA, 30% to 210%
  • for Type B, 20% to 210%. Test of tripping speed (T):- Settings as of right now1: 10-30-100-300-500-1000mA - VAR
  • 10-30-100mA A multiplier of 0.5, 1, and 5 Range of measurements: 510ms, 160ms (RCD Type)
  • 310ms, 50ms (RCD Type G). Measurement of AC voltage:- 500 volts 0.1V as the resolution Accuracy from 45 to 66 Hz: 0.8% plus 3 counts 360 k input impedance 660V rms overload protection Test for Earth Resistance (RE):- the frequency is128 Hz. Range: 200Ω / 2000Ω 0.1 / 1 resolution Voltage at output: 25V Connect Fluke:- Operating systems iOS 8 and later or Android 4.4 and later support Fluke Connect. General:- AA x 6 batteries, Cat III to 500V
  • Cat IV to 300V of excess voltage Performance: Second Editions of EN61557-1 through EN61557-7 and EN61557-10 Size: 10 x 25 x 12.5 cm (L x W x H). IP-40 Sealing Safety: Complies with EN61010-1 Ed 2.0 (2001-02), UL61010, ANSI/ISA -s82.02.01 2000, and CAN/CSA c22.2 No. 1010 second edition regulations. Weight (batteries included): 1.3 kg Measuring Insulation Resistance:- Test voltage accuracy (at the specified test current): +10%, -0% Ranges of insulation resistance: 20 to 50 M, 20 to 100 M, 20 to 200 M, 20 to 200 M, and 20 to 200 M. Resolution: 0.01M/0.1M, 0.01M/0.1M, 0.01M/0.1M, 0.01M/0.1M/1M, and 0.01M/0.1M/1M Test voltages: 50, 100, 250, 500, and 1000V Test voltage: 50, 100, 250, 500, and 1000 volts. Test currents of 1 mA at 50 k, 100 k, 250 k, 500 k, and 1 mA at 1 m Impedance of Loops and Lines (ZI):- High current m mode
  • range: 10
  • 0.001
  • Resolutions of 0.01, 0.1, and 1 PSC Test for Prospective Earth Fault Current:- 1000A to 10kA (50kA) range 1A/0.1kA resolution Calculation: To determine the prospective earth fault current (PEFC) or prospective short current (PSC), divide the measured loop resistance (L-PE) or line resistance (L-N) by the actual mains voltage, accordingly. RCD Testing and Kinds of RCD Testing:- Model 1664: A, AC, B5, S RCD type: AC1
  • G2, S3. Notes: For Type A IN &gt
  • 10 mA, 130% to 150%
  • for Type A IN = 10 mA, 30% to 210%
  • for Type B, 20% to 210%. Measurement of RCD/FI-Tripping Current and Ramp Testing (IΔN):- 30% to 110% of the RCD rated current is the current range.1 10% of IN2 as a step size Dwell time: Type G: 300 ms
  • Type S: 500 ms Measurement precision: 5% Trip current ranges that have been specified (EN 61008-1) are as follows: 50% to 100% for Type AC, 35% to 140% for Type A (&gt
  • 10 mA), 35% to 200% for Type A (10 mA), 50% to 200% for Type B, and 25% for Type B. Reactions to AC, general no delay, time delay, pulsed signal, and smooth DC signal are noted. Test of tripping speed (ΔT):- Settings as of right now1: 10-30-100-300-500-1000mA - VAR
  • 10-30-100mA A multiplier of 0.5, 1, and 5 Range of measurements: 510ms, 160ms (RCD Type)
  • 310ms, 50ms (RCD Type G). Notes: Only type AC may use 1000mA, type A can only use 700mA in VAR mode, and type B cannot use VAR mode.
  • To find damaged N wires, check the wiring'
  • s polarity. Calculates projected short (PSC/IK) and prospective earth fault current (PEFC/IK). Contains Z-max memory for loop tests so you can quickly determine the highest loop test value. loop and line resistance, as well as insulation resistance, are measured. Test the continuity of the motor windings. Test the ramp by measuring the RCD switching time and tripping level. Trip time and current for RCD type A and AC are measured in one test. RCD variable current is measured. gives access to a special zero adaptor for quick, precise, and reliable test lead and main cord compensation. provides an RCD test cycle that is automatic. Phase-sequence signal RCD testing, ramp testing, and continuity testing 500V for Cat III and 300V for Cat IV Security rankings Ground Volt Touchpad recognises elevated earth voltage Smartphone connectivity for Fluke Connect and FlukeCloud Insulation PreTest recognises appliances to prevent harm. DC test voltages of 50V, 100V, 250V, 500V, and 1000V for insulation AC voltage, insulation resistance, loop impedance, and line impedance (ZI) measurements measurement of the earth resistance, tripping speed, potential earth fault current, and current generated by the RCD/FI includes all required add-ons, such as a remote probe and an FTP fused test probe set. time-saving automatic test feature strong construction and lightweight portability